Service difficulty report · Sensor · Bombdr DHC8402

Difficulty date
July 19, 2019
Submitted
July 19, 2019
Operation
Air carrier
Aircraft
N447QX
Make and model
Bombdr DHC8402
Aircraft serial
4364
Aircraft time
19,147 hours, 20,563 cycles
Part
Sensor
Condition
Malfunctioned
Location
Apu
Stage of operation
TX
How discovered
O
Nature of condition
A
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APU START ABORTED DUE TO RAMP REPORT FLAME FROM EXHAUST ( APU INOP ). RESET APU CB L3. OPS TESTED APU PER AMM 49-00-00-869-801. APU FAILED TO START. RE-ACCOMPLISHED MEL MTX PROCEDURE TO CONTINUE MEL 49-00-1. APU CB L3 IS PULLED/COLLARED. CDS SHOWED 270-0/RUN (DMM TEMP SENSOR) AND 054-2/RUN (IGNITOR PLUG A OPEN) FAULTS. PLACED APU ON MEL 49-00-1.