Service difficulty report · Circuit Breaker · Bombdr DHC8402

Difficulty date
December 6, 2019
Submitted
December 9, 2019
Operation
Air carrier
Aircraft
N446QX
Make and model
Bombdr DHC8402
Aircraft serial
4363
Aircraft time
20,169 hours, 21,670 cycles
Part
Circuit Breaker
Condition
Tripped
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE IN CRUISE, CREW RECEIVED ENG ADPT HEAT 2 CAUTION ENG INTAKE HTR ADVISORY LIGHT WENT OUT AT THE SAME TIME. RETURNED TO FIELD. LANDING UNEVENTFUL. REMOVED FROM SERVICE. FOUND "INTAKE LIP HTR ENG 2" CIRCUIT BREAKER POPPED. PUSHED C/B IN, CLEARED CDS FAULT REF GPM 9.2.2.1. PERFORMED ENGINE AIR INTAKE ANTI-ICING OPS TEST REF Q400 AMM 30-21-00-710-801. OPS CHECK GOOD. NO FAULTS RETURNED. CLEAR DEFECT, NO OTHER DEFECTS NOTED. RETURNED TO SERVICE. NO PARTS REPLACED.