What was found
WHEN AIRCRAFT POWER WAS TURNED OFF AFTER COMPLETION OF TOW EMERGENCY LIGHTS ILLUMINATED. VERIFIED EMERGENCY IT SWITCH WAS IN OFF POSITION. TURNED ON AIRCRAFT POWER. NOTICED EMERGENCY LTS DISARMED CAUTION LIGHT WAS NOT ILLUMINATED. TURNED FLIGHT DECK EMERGENCY LIGHT SWITCH FROM OFF TO ARMED TO ON THEN BACK TO OFF. CAUTION LIGHT DID NOT ILLUMINATE. CYCLED EMERGENCY LIGHT SWITCH ON WING BULKHEAD FROM NORM TO ON THEN BACK TO NORMAL. CAUTION LIGHT ILLUMINATED. TURNED OFF POWER. EMERGENCY LIGHTS REMAINED OFF. REPLACED EMERGENCY LIGHT SWITCH AND BODY MODULE ON WING BULKHEAD IAW DHC-8-400 MM TASK #S 33-51-05-000-801 PARAGRAPHS 1 THRU 4A STEP (3)Y AND 33-51-05-400-801 PARAGRAPHS 1, 2, 3, 4A STEPS (2) (3) & (4), AND PARAGRAPH 5. EMERGENCY LIGHT SYSTEM OPERATIONAL TEST GOOD SEVERAL TIMES IAW DHC-8-400 MM TASK 33-51-00-710-802. ALL INDICATIONS NORMAL DURING AND AFTER TESTS.