As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLAP POWER CAUTION ILLUMINATED WHEN FLAPS WERE SELECTED FROM 15-35 DEGREE. ACCOMPLISHED E/A CHECKLIST FLAP POWER CAUTION ILLUMINATED AGAIN. LANDING UNEVENTFUL. REMOVED FROM SERVICE. FOUND FAULT ECS CONTINOUS BIT ERASED FAULTS PER Q400 AMM 45-00-27-743-802. PERFORMED FLAPS OPS TEST PER Q400 AMM 27-50-00-710-801. OPS TEST GOOD. FAULT AND CAUTION DID NOT RETURN. RETURNED TO SERVICE.