Service difficulty report · Shutoff Valve · Bombdr DHC8402

Difficulty date
September 8, 2020
Submitted
September 9, 2020
Operation
Air carrier
Aircraft
N453QX
Make and model
Bombdr DHC8402
Aircraft serial
4489
Aircraft time
11,685 hours, 12,627 cycles
Part
Shutoff Valve
Part number
8209026
Part serial
2006060234
Condition
Malfunctioned
Location
Zone 100
Part time
25,977 hours, 27,850 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HAD TO ABORT TAKEOFF CAUSE AT 77 KTS THE NR 1 + NR 2 BLEED HOT LIGHT + CAUTION CAME ON. RAN NR 1 + NR 2 BLEED HOT CHECKLIST AND THE WENT OFF. DID NOT HAVE TO USE EXCESSIVE BRAKING. REMOVED FROM SERVICE. INTERROGATED CDS FOUND FAULTS: 3003-PACK FCV; 3001-PACK FCV ON LEFT CHANNEL; 3003-PACK FCV; 1007-RNAPRSOV RT CHANNEL FAULTS WOULD NOT CLEAR. REMOVED & REPLACED PACK INLET TEMP SENSOR, IAW Q400 AMM TASKS 21-52-11-000-801 AND 400-801. REMOVED & REPLACED PACK FLOW CONTROL SOV, IAW AMM TASKS 21-52-01-000-801 AND 400-801. ERASED FAULT CODES. RAN BOTH ENGINES FOR 15 MINUTES. C/W PACK FCV OPS TEST. OPS TEST GOOD, NO FAULTS OR CAUTIONS ILLUMINATED. LEAK CHECK C/W, NO LEAKS FOUND. RETURNED TO SERVICE.