Service difficulty report · Shutoff Valve · Bombdr DHC8402

Difficulty date
December 4, 2020
Submitted
December 4, 2020
Operation
Air carrier
Aircraft
N447QX
Make and model
Bombdr DHC8402
Aircraft serial
4364
Aircraft time
21,594 hours, 23,381 cycles
Part
Shutoff Valve
Part number
8209713
Part serial
2008120900
Condition
Malfunctioned
Location
Bleed System
Part time
21,441 hours, 23,315 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

REJECTED TAKEOFF DUE TO NR 1 BLEED HOT CAUTION LIGHT ON TAKEOFF ROLL. NR 2 BLEED HOT CAUTION SHORTLY AFTER CLEARING RUNWAY, RAN CHECKLIST. CAUTION LIGHTS CLEARED. BLEED FLOW SELECTOR WAS IN "MIN" DUCT & CABIN TEMPS APPEARED TO BE NORMAL. TAKEOFF REJECTED BELOW 80 KTS. REMOVED FROM SERVICE. INTERROGATED CDS AND FOUND FAULT 3003-PACK FCV ON BOTH CHANNELS. C/W FIM TASK 36-20-00-810-805. OPERATIONS TEST WAS GOOD AND FAULTS REMAINED EXTINGUISHED. DUE TO HAVING 3003 PREVIOUSLY R & R PACK FLOW CONTROL AND SHUTOFF VALVE, IAW Q400 AMM TASKS 21-52-01-000-801 AND 21-52-01-400-801 STEPS 1-5C. C/W REMAINING STEPS OF Q400 AMM TASK 21-52-01-400-801, LEAK CHECK & OPERATIONS CHECK IS GOOD. NO FAULTS PRESENT IN CDS UNDER ECS SYSTEM. C/W BLEED AIR OPERATIONS TEST, REF Q400 AMM TASK 36-11-00-710-802. OPERATIONS TEST IS GOOD. ALL INDICATIONS ARE NORMAL, NO FURTHER ACTION REQUIRED. AIRCRAFT RETURNED TO SERVICE.