What was found
ON DEPARTURE #2 AC GEN CAUTION ILLUMINATED. RAN CHECKLIST THE GEN DID NOT RESET. MONITORED THE LOAD ON ALL 3 PHASES OF THE #1 AC GEN. NO PHASE APPROACHED OVER LOAD. RETURNED TO FIELD. REMOVED FROM SERVICE. R&R AGCU #2. OPS CHECK GOOD. FAULT LIGHT EXTINGUISHED AND DID NOT RETURN. NO FURTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.