As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ABORTED TAKE OFF DUE TO ILLUMINATION OF #2 BLEED HOT CAUTION - ABORTED OCCURRED BELOW 70 KIAS, NO REVERSE AND MINIMAL BREAKING APPLIED. REMOVED FROM SERVICE. INTERROGATED CDS. FOUND FAULT 1006-R NAPRSOV. COMPLIED WITH FIM 36-10-00-810-801. REPLACED RIGHT NACELLE SHUTOFF VALVE IAW AMM 36-11-19-000/400-801. OPS TEST GOOD. BLEED HOT CAUTION DID NOT ILLUMINATE. RETURNED TO SERVICE.