Service difficulty report · Bleed Air Sys · Emb ERJ170200LR

Difficulty date
November 19, 2022
Submitted
November 21, 2022
Operation
Air carrier
Aircraft
N438QX
Make and model
Emb ERJ170200LR
Aircraft serial
4243
Aircraft time
28,708 hours, 31,076 cycles
Part
Bleed Air Sys
Condition
Warning Message
Location
Nr 2
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TAKEOFF ABORTED DUE TO #2 BLEED HOT CAUTION ILLUMINATED JUST AFTER BRINGING THE PCL'S UP TO THE RATING DETENT. ALL BLEED AIR TEMPS WERE IN THE NORMAL RANGE AND BLEED FLOW WAS IN THE MIN POSITION. AFTER COMPLETING THE #2 BLEED HOT E&A CHECKLIST, THE #2 BLEED HOT CAUTION EXTINGUISHED AND REMAINED OFF FOR THE REMAINDER OF THE FLT. REMOVED FROM SERVICE. #2 BLEED HOT CAUTION NOT ILLUMINATED AT GATE. CDS SHOWED NO RELATED FAULTS ON #2 ENG BLEED SYSTEM. C/W FIM TASK 36-20-00-810-801. OPS TEST OF BLEED AIR IS GOOD. #2 BLEED HOT CAUTION DID NOT RETURN AND NO OTHER DEFECTS NOTED. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.

More about the Emb ERJ 170-200 LR