As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION, AFT SERVICE DOOR CUTOUT LOWER BEAM ON UPPER EDGES OF FORWARD AND AFT ESCAPE SLIDE FITTING CUTOUTS. BLENDED OUT CORROSION IN AFT PAX DOOR CUTOUT LOWER BEAN ON FWD AND AFT ESCAPE SLIDE FITTINGS SRM 51-10-03. ALLOWABLE DAMAGE .080" (FWD) LOSS .025" LENGTH .961" WIDTH 121" (AFT) LOSS-.010" LENGTH .667" WIDTH .65". BOTH FOUND TO BE WITHIN LIMITS SRM 53-10-11-/AD02.