As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MTX FOUND L2 DOOR FWD FLOOR FITTING OUT OF ADJUSTMENT. INSTALLED PINS IAW E175 AMM TASK 52-00-23-900-801-A STEPS 8(D)(E). CONDUCTED INITIAL MEASUREMENT OF FLOOR FITTINGS, FOUND FWD FITTING TO BE AT .350 AND AFT FITTING TO BE AT .300, ADJUSTED FORWARD FLOOR FITTING IAW E175 AMM TASK 52-12-00-820-801-A. NEW FWD DIMENSION FOUND TO BE AT .256. OPS TEST GOOD, NDN. PINTS REMOVED IAW E175AMM TASK 52-00-23-910-011-A.