What was found
CORROSION IN RH IB FLOOR BEAM BETWEEN FR 17-18. REMOVED AND REPLACED RH IB FLOOR BEAM BETWEEN FR 12-20. REF SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION IN RH IB FLOOR BEAM BETWEEN FR 17-18. REMOVED AND REPLACED RH IB FLOOR BEAM BETWEEN FR 12-20. REF SRM 51-40-08.