Service difficulty report · Gasket · Emb ERJ170200LR

Difficulty date
October 31, 2024
Submitted
November 4, 2024
Operation
Air carrier
Aircraft
N622QX
Make and model
Emb ERJ170200LR
Aircraft serial
17000651
Aircraft time
19,739 hours, 12,977 cycles
Part
Gasket
Part number
17016603001
Condition
Missing
Location
Zone 100
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 2041. ON CLIMB OUT AROUND 18,000 FT BLEED 2 LEAK CAUTION MSG. RAN CHECKLIST. MESSAGE REMAINED. ON LANDING BLEED 2 FAIL MESSAGE. REMOVED FROM SERVICE. C/W E175 FIM TASK 36-11-00-810-837-A FOR FC 36113001AMR. FOUND NVM READS BLEED 2 OVERHEAT CONDITION AT EVENT LOCATION 15.68(CH1) AND 1350(CH2). REF E175 AMM TASKS54-50-21-000/400-801-A, 54-50-21-000/400-801-A. PERFORMED VISUAL INSPECTION OF NVM REPORT LOCATIONADJACENT AREAS, NO DEFECTS FOUND. PERFORMED NVM RESET. PERFORMED ENG BLEED SYS OPS TEST IAW E175 AMM 36-11-00-710-801-A. OPS TEST FAILED. BLEED 2 ILLUMINATED AT 85% N2 #2 ENG WITH CH 2 IN CONTROL. NEW EVENT LOCATION SHOWING AT 9.48 (CH1) 12.75 (CH2). UPON INSPECTION FOUND #2 ENG FAN AIR VALVE OUTLET DUCT TORN 5" BELOW RH PYLON ODS ELEMENT . REMOVED PANEL 429 NR AND FAN AIR VALVE OUTLET DUCT PER APPLICABLE STEPS OF E175 AMM TASK 36-11-09-400-801-A AND RETURNED A/C TO NORMAL CONFIGURATION. ENGINE BLEED OPS TEST PER E175 AMM 36-11-00-710-801-A FAILED. FC 36112210AM2 FLAGGING IN CMC. R/R RH NAPRSOV IAW E175 AMM 36-11-03-000/400-801-A, NO LEAKS NOTED. ENG BLEED SYS OPS TEST FAILED. SUSPECT LEAKAGE FROM RH PRECOOLER OUTLET DUCT. REMOVED RH PRECOOLER OUTLET DUCT REF E175 AMM 36-11-08-000-804-A. FOUND 4" OF INTERFACE GASKET MISSING ON UPPER SIDE. INSTALLED SERVICABLE FROM STOCK GASKET AND REINSTALLED OUTLET DUCT REF E175 AMM 36-11-08-400-804-A. OPS CHECK GOOD. NO FURTHER LEAKAGE NOTED. A/C RETURNED TO SERVICE.

More about the Emb ERJ 170-200 LR