What was found
LBL 11 FLOOR TRACK APPEARS TO HAVE CORROSION AROUND FASTENER AT FR 17. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-10 AND REPAIRED FR 17 LBL 11 IAW SRM 53-10-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LBL 11 FLOOR TRACK APPEARS TO HAVE CORROSION AROUND FASTENER AT FR 17. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-10 AND REPAIRED FR 17 LBL 11 IAW SRM 53-10-10.