Service difficulty report · Throttle · Emb ERJ170200LR

Difficulty date
May 22, 2025
Submitted
May 23, 2025
Operation
Air carrier
Aircraft
N657QX
Make and model
Emb ERJ170200LR
Aircraft serial
17000943
Aircraft time
5,059 hours, 3,982 cycles
System (JASC)
7603 · Power Lever
Part
Throttle
Condition
Faulted
Location
Zone 200
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TECHNICAL ORDER – PARTS REPLACEMENT – THROTTLE QUADRANT TCQ REPLACEMENT DUE TO FAULT TREND IN AHEADPRO. " A/T FAIL" CAUTION WHEN "A/T" PUSHED ON MAIN PANEL FOR T.O CYCLED A/T DISC SWITCHES ON THROTTLES WHICH CLEARED "A/T FAIL" CAUTION. RESELECTED "A/T" ON MAIN PANEL. AUTOTHROTTLE SYSTEM OPPERATED NORMALLY REST OF FLIGHT. REMOVED AND REPLACED TCQ IAW AMM 76-11-01-000/400-801-A. OPS TEST GOOD.