EMERGENCY LIGHT BATTERY FAULT ON EICAS AFTER POWER UP. REMOVED FROM SERVICE. IAW FIM 33-50-00-810-801-A STEPS 7.C. FAULT WAS NOT PRESENT NO FURTHER DEFECT NOTED. RETURNED TO SERVICE. NO PARTS REPLACED.