What was found
FLIGHT 2457. ELEC PUMP SYS 3A (HYDR) (C8) CIRCUIT BREAKER FOUND TRIPPED. DIVERTED AND ACCOMPLISHED UNEVENTFUL LANDING. REMOVED FROM SERVICE. FOUND FAULTS 29100001UT1, 29120007HP1, 29310001HP2. RESET BREAKER PER GPM 9.2.2.1 CW FIM 29-31-00-810-816-A. DETERMINED TO BE A TRANSITORY CONDITION. SYSTEM 3A HYD PUMP OP CHECKS GOOD REF. AMM 29-12-00-710-810-A. NO HISTORY IN THE LAST 3 MONTHS. OK FOR SERVICE. FAULTS DID NOT RETURN. NO PARTS REPLACED RETURNED TO SERVICE.