As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY FLOOR PATCH LIGHTING HAS ISSUE. REMOVED FROM SERVICE. REPLACED PHOTOLUMINESCENT INDICATOR STRIPS IN CENTER ISLE ON BOTH SIDES OF ROWS 1-2 AND THE L/H STRIP BETWEEN ROWS 4 AND 6, IAW E175 AMM 33-50-21-00-801-A/400-801-A. NO FURTHER DEFECTS NOTED AT THIS TIME. RETURNED TO SERVICE.