Service difficulty report · Dampener · Emb ERJ170200LR

Difficulty date
August 5, 2026
Submitted
August 8, 2026
Operation
Air carrier
Aircraft
N633QX
Make and model
Emb ERJ170200LR
Aircraft serial
17000719
Aircraft time
21,084 hours, 14,925 cycles
Part
Dampener
Part number
21240001405
Part serial
04575
Condition
Leaking
Location
Control Collum
Part time
21,084 hours, 14,925 cycles
Stage of operation
TX
How discovered
O
Nature of condition
K, F
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 2452. ELEVATOR CONTROL RESISTS MOVEMENT & BINDS. ISSUE PRESENT ON BOTH CONTROLS. IF CONTROLS PULLED FULL BACK & RELEASED, CONTROLS TAKE 2 SECS TO RETURN TO CENTER. RETURNED TO GATE REMOVED FROM SERVICE. C/W FIM 27-30-00-810-806-A. ELEVATOR COMMAND HARD TO MOVE OR SLOW, TASKS 27-30-00-810-009A-27-300-00-813-008-A E (2) 27-30-00-813-014-A, 27-30-00-813-016-A V1. CONTROL COLUMN REMAINS DISCONNECTED. FOUND PILOT'S SIDE CONTROL COLLUM DAMPER LEAKING FLUID. R & R THE CONTROL COLLUM DAMPER IAW AMM 27-31-02-000-801-A, 27-31-02-400-801-A. C/W ELE CONTROL SYS OPS CHK. OPS CKD GOOD. NO OTHER DEFECTS. IAW AMM 27-30-00-710-801-A. COMPLETED FREEDOM OF MOVEMENT CHK, ENSURED FULL TRAVEL & VERIFIED PROPER DIRECTION OF MOCEMENT. NO DEFECTS NOTED IAW GPM 9.2. RE-CONNECTED CONTROL COLLUM IAW AMM 27-31-06-840-801-A.