Service difficulty report · Oxygen Box · Emb ERJ170200LR

Difficulty date
October 11, 2026
Submitted
October 14, 2026
Operation
Air carrier
Aircraft
N648QX
Make and model
Emb ERJ170200LR
Aircraft serial
17000789
Aircraft time
19,618 hours, 13,959 cycles
Part
Oxygen Box
Part number
CDSP4652505
Condition
Malfunctioned
Location
Zone 200
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 9987. FA 2 DISPENCING UNIT IN FWD GALLEY IS INOP. FLIGHT ATTENDANT O2 DISPENCING UNIT IN FWD LAVIS INOP. PLACED ON MEL. MEL'S CLEARED. T/S FWD G1 GALLEY O2 BOX INOP. OXYGEN BOX WILL NOT OPEN DURING PAX OXYGEN SYS OPS TEST IAW AMM 35-20-00-710-801-A, BEGAN TO PERFORM ELECTRICAL POWER CHECK ON CONNECTOR P0362 REF WM 35-21-50. IAW SWPM 20-64-00. FOUND PIN V ON P0362 READS OL TO GROUND – FAULT (~ 0 OHMS EXPECTED). FOUND W102-01748-20N TO BE PULLED OUT OF TERMINAL LUG GS0938. RE-TERMINATED GS0938 ON W102-01748-20N. IAW SWPM 20-41-10, SWPM 20-21-10, AMM 20-13-21-910-801-A & AMM 20-13-21-910-803-A. PIN V ON P0362 NOW READS 0 OHMS TO GROUND GOOD. REMOVED FWD LAV O2 BOX IAW AMM 35-20-05-000-801-A. CHK FOR 28 VDC BETWEEN LAV O2 BOX SPLICE LV2-TJ1 INTERCONNECTS ERJ-LV504-22 & ERJ-LV505-22N WHILE PERFORMING OPS TEST OF THE PASSENGER OXYGEN SYSTEM IAW E175 AMM 35-20-00-710-801-A, WM 25-41-51-1 AND SWPM 20-64-00: 28 VDC NOTED BETWEEN INTERCONNECTS DURING TEST – GOOD. HOWEVER, NOTED THAT ERJ-LV504-22 AND ERJ-LV505-22N FOUND TO BE CONNECTED TO SPLICE LV2-TJ1 INCORRECTLY. IAW E175 WM 25-41-51-1 MOVED INTERCONNECTS TO CORRECT CONNECTIONS. ERJ-LV504-22 TO PIN A AND ERJ-LV505-22N TO PIN B IN SPLICE LV2-TJ1. PERFORMED PASSENGER OXYGEN SYSTEM OPS TEST. IAW E175 AMM 35-20-00-710-801-A. FWD LAV O2 BOX NOW OPERATES AS NORMAL. RETURNED TO SERVICE.

More about the Emb ERJ 170-200 LR