What was found
CRACK IN FRAME JOINT SPLICE ANGLE AT STATION X 136.800 AND STRINGER 15A RIGHT SIDE. REMOVED AND REPLACED FRAME PER DHC SRM 51-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK IN FRAME JOINT SPLICE ANGLE AT STATION X 136.800 AND STRINGER 15A RIGHT SIDE. REMOVED AND REPLACED FRAME PER DHC SRM 51-40-11.