What was found
PDX - UPPER FORWARD SPAR LEADING EDGE ATTACH ANGLE IS GOUGED IN THE AREA FOR LEADING EDGE 613CR ATTACHMENT. REPAIRED IAW DHC-8-100 M/M 20-32-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PDX - UPPER FORWARD SPAR LEADING EDGE ATTACH ANGLE IS GOUGED IN THE AREA FOR LEADING EDGE 613CR ATTACHMENT. REPAIRED IAW DHC-8-100 M/M 20-32-02.