What was found
DURING AUTO-PILOT TROUBLESHOOTING, INSPECTOR FOUND MAJOR BIND IN ELEVATOR CONTROLS. INSPECTION REVEALED ELEVATOR CABLE IN AFT FUSELAGE MISROUTED, DURING MAINTENANCE, (5 HOURS PREVIOUS) CAUSING ELEVATOR CABLE TO RUB SEVERELY ON HORIZONTAL STABILIZER STRUCTURE, DAMAGING IT. CABLE WAS IMPROPERLY ROUTED JAMMING ELEVATOR DUE TO CABLE RUBBING STRUCTURE. EVIDENTLY NO INSPECTION COMPLETED AFTER MAINTENANCE.