What was found
WHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON RT SEAT TRACK BEAM FR 89 TO FR 90, AFT GALLEY. MAINTENANCE REMOVED CORROSION, PERFORMED EDDY CURRENT INSPECTION AND APPLIED PRIMER AND TOP COAT, PER EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.