What was found
WHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON FLOOR GUSSET AT FR 90 AT WASTE TANK FORWARD MOUNT. MAINTENANCE REMOVED AND REPLACED GUSSET PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON FLOOR GUSSET AT FR 90 AT WASTE TANK FORWARD MOUNT. MAINTENANCE REMOVED AND REPLACED GUSSET PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.