What was found
GENERATED WHILE A/C WAS IN 72 MONTH CHECK, WASTE ACCESS DOOR CUTOUT STRUCTURE HAS SIGNS OF CORROSION ON I/B FWD CORNER. MAINTENANCE CLEANED AND REMOVED CORROSION AND COMPLETED OPS CHECK IAW EMB 170 AMM 38-32-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GENERATED WHILE A/C WAS IN 72 MONTH CHECK, WASTE ACCESS DOOR CUTOUT STRUCTURE HAS SIGNS OF CORROSION ON I/B FWD CORNER. MAINTENANCE CLEANED AND REMOVED CORROSION AND COMPLETED OPS CHECK IAW EMB 170 AMM 38-32-00.