WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL ON FR90 CROSSBEAM TO LT LONGITUDINAL BEAM. MX REPLACED SPLICE PANEL P/N 170-60257.001 IAW EMB170 SRM. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.