What was found
WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL FR90 CROSSBEAM TO LT INTERCOSTAL. MX REPLACED GUSSET PLATE IAW EMB 170 SRM. P/N 170-60261-001 A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL FR90 CROSSBEAM TO LT INTERCOSTAL. MX REPLACED GUSSET PLATE IAW EMB 170 SRM. P/N 170-60261-001 A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.