What was found
WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON CENTER SHEAR PANEL AT FR87-88 FLOOR CROSS BEAMS. MX REPLACED CENTER SHEAR PANEL IAW EMB 170 SRM. P/N 170-65928, A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON CENTER SHEAR PANEL AT FR87-88 FLOOR CROSS BEAMS. MX REPLACED CENTER SHEAR PANEL IAW EMB 170 SRM. P/N 170-65928, A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.