What was found
WHILE ACFT WAS IN FOR HEAVY CHECK. LEVEL 2 CORROSION WAS FOUND ON A SHEAR CLIP AND A INTERCOSTAL BRACKET AT FR 87 BETWEEN STR 27R & 28R. MX R & R SHEAR CLIP AND INTERCOSTAL BRACKET, SHEAR CLIP, PN 170-66041-002 AND INTERCOSTAL BRACKET, PN 170-87562-001 WITH FABRICATED PARTS FROM 7475-T761, 0.050 MATERIAL. REF PO 024102-2011 IAW SRM 51-40-02, 51-41-01 & 51-41-02. ACFT IS CURRENTLY STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.