What was found
DURING HEAVY CHECK, FOUND RT FLOOR SUPPORT BETWEEN FRAMES 12-14 CORRODED. R & R FLOOR SUPPORT IAW SRM 51-40-02, 51-40-04, 51-41-02, 51-43-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK, FOUND RT FLOOR SUPPORT BETWEEN FRAMES 12-14 CORRODED. R & R FLOOR SUPPORT IAW SRM 51-40-02, 51-40-04, 51-41-02, 51-43-04.