DURING HEAVY CHECK, RT FLOOR TRACK FRAME IS CORRODED. MX CUT OUT DAMAGE RT FLOOR TRACK FABRICATED, LOCATED, DRILLED, ALODINED, PRIMED DOUBLER AND FILLER IAW SRM 53-10-10 INSTALLED REPAIR SRM 53-10-10 TOP COAT APPLIED IAW 51-23-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK, RT FLOOR TRACK FRAME IS CORRODED. MX CUT OUT DAMAGE RT FLOOR TRACK FABRICATED, LOCATED, DRILLED, ALODINED, PRIMED DOUBLER AND FILLER IAW SRM 53-10-10 INSTALLED REPAIR SRM 53-10-10 TOP COAT APPLIED IAW 51-23-06.