What was found
DURING HEAVY CHECK LT WING HYD PRESSURE LINE IS LOOSE AT SPAR 3 PASS THRU WITH POSSIBLE DAMAGE TO SPAR. MX LT WING SPAR 3, FCBS 57-10-00-001 BETWEEN RIB 4 AND 5 WAS REPAIRED IAW ETD 2014-170-026275, REV A. THIS IS A PERMANENT REPAIR REQUIRES RE-INSPECTION IAW ETD 2014-170-026275, REV A, PRE MOD SB 170-57-008-0002 EXTERNAL SDI THRESHOLD OF 20000 F/C INTERVAL OF 10000 F/C IS SUFFCIENT AND IS MET USING INSPECTION REQUIREMENTS MPG/MRBR, REV 8, THRESHOLD COUNT SINCE NEW TRANSFERED TO NONMEL DMI NR 477509/3 FOR 6 MONTHS TO ALLOW INCORPORATION TO THE INSPECTION MAINTENANCE PROGRAM IAW GMM 9.5.4, PN 170-32014-427, SPAR 3.