What was found
DURING HEAVY CHECK, HYD PRESSURE LINE JAMNUT LOOSE & CHAFING ON SPAR 3 LT WING JUST OTBD OF RIB 4. MX LT SPAR 3, FCBS57-10-00-001, BETWEEN RIB 4A-6 WAS REPAIRED IAW ETD 2014-170-053811, REV B. FOR WORK DETAILS THIS REPAIR REQUIRES REINSPECT IAW ETD 2014-170-053811 BY USING FOLLOWING TASK. TASK 57-50-003-00001, INTERNAL DET THRESHOLD OF 25400FC OR 33782FH INTERVAL OF 24243FC OR 32243FH, IS SUFFIEICIENT AND IS MENT USING INSPECTION REQUIREMENTS. THRESHOLD IS COUNTED SINCE NEW TRANSFERED TO NON-MEL DMI 410693/3 FOR 6 MONTHS TO ALLOW INCORPORATION. INSPECTION MAINTENANCE PROGRAM IAW GMM 9.5.4. NO ITEMS WERE CHANGED.