What was found
DURING HEAVY CHECK, RT CENTER FLOOR SUPPORT STRAP BETWEEN FRAMES 85-86 FOUND CORRODED. MX R & R FLOOR SUPPORT STRAP IAW SRM 51-41-01, 51-43-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK, RT CENTER FLOOR SUPPORT STRAP BETWEEN FRAMES 85-86 FOUND CORRODED. MX R & R FLOOR SUPPORT STRAP IAW SRM 51-41-01, 51-43-03.