What was found
DURING HEAVY CHECK, EDDY CURRENT INSPECTION OF FASTENER HOLE RT SPAR 3 FOUND CRACK AT 3 O`CLOCK POSITION. MX REAMED HOLE TO .513, REMOVED CRACKS AND INSTALLED BUSHING IAW ETD 2015-170-009715, SEE CONTINUATION CARDS C1-C2 FOR WORK DETAILS REPAIR REQUIRES INSPECTION TASK 57-01-008-0003 EXTERNAL DET THRESHOLD OF 33000 F/C INTERVAL OF 16900 F/C THRESHOLD COUNTED SINCE NEW ISSUED DMI R92477/2 ISSUED DAMAGE TRACKER NR 22 FOR REPAIR IAW GMM 5.16.1.