What was found
DURING HEAVY CHECK, R/H CENTER GUSSET PLATE AT FRAME 90 HAS CORROSION. MAINTENANCE R & R RT CENTER GUSSET PLATE AT FRAME 90 IAW SRM 51-40-02, 51-21-01. PN 170-60257-001 GUSSET. ACFT REMAINS UNTIL HEAVY CHECK IS COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK, R/H CENTER GUSSET PLATE AT FRAME 90 HAS CORROSION. MAINTENANCE R & R RT CENTER GUSSET PLATE AT FRAME 90 IAW SRM 51-40-02, 51-21-01. PN 170-60257-001 GUSSET. ACFT REMAINS UNTIL HEAVY CHECK IS COMPLETED.