What was found
WHILE IN HEAVY CHECK WAS REPORTED THAT NR 1 HINGE FITTING INBD BUSHING ON LT ELEVATOR IS CORRODED. MAINTENANCE R & R NR 1 HINGE FITTING INBD BUSHING ON LT ELEVATOR IAW AMM 20-10-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HEAVY CHECK WAS REPORTED THAT NR 1 HINGE FITTING INBD BUSHING ON LT ELEVATOR IS CORRODED. MAINTENANCE R & R NR 1 HINGE FITTING INBD BUSHING ON LT ELEVATOR IAW AMM 20-10-08.