What was found
DURING HEAVY CHECK, LT SPAR 3 BULKHEAD AFTER REAMING FOUND CRACKS IN HOLE. MAINTENANCE REAMED HOLE TO .481, REMOVED ALL CRACKS, INSTALLED OVERSIZED BUSHING IAW ETD 2015-170-094791, REQUIRES INSPECTION TASK 57-01-008-0003 EXTERNAL DET THRESHOLD OF 33000 F/C AT INTERVAL OF 16900 F/C THRESHOLD COUNTED SINCE NEW ISSUED DMI R175769/1 ISSUED DAMAGE TRACKER NR 13 IAW GMM 5.16.1.