Difficulty date
October 16, 2015
Submitted
October 19, 2015
Operation
Air carrier
Aircraft
N415YX
Make and model
Emb ERJ170200LR
Aircraft serial
17000378
Aircraft time
5,166 hours, 3,570 cycles
Part
Pump
Part number
5116404
Part serial
K2359
Condition
Split
Location
Hyd System
Part time
5,166 hours, 3,570 cycles
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED A HYD SYSTEM 1 LOW QUANTITY MESSAGE. DID NOT DECLARE AN EMERGENCY AND DIVERTED, LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 1 ENGINE DRIVEN PUMP SPLIT AT INTERFACE. MAINTENANCE R & R ENGINE DRIVEN PUMP IAW AMM AND OPS CHECKED GOOD.