What was found
WHILE ACFT WAS IN FOR HEAVY CHECK, FOUND CORROSION ON STR 19R BETWEEN FRAME 83/84. MAINTENANCE INSTALLED NEW SHEAR PANEL AT FRAME 16 LT SIDE PN 170-12118-001 IAW SRM 51-41-02. ACFT REMAINS IN MAINTENANCE FOR COMPLETION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE ACFT WAS IN FOR HEAVY CHECK, FOUND CORROSION ON STR 19R BETWEEN FRAME 83/84. MAINTENANCE INSTALLED NEW SHEAR PANEL AT FRAME 16 LT SIDE PN 170-12118-001 IAW SRM 51-41-02. ACFT REMAINS IN MAINTENANCE FOR COMPLETION.