What was found
WHILE ACFT WAS IN FOR HEAVY CHECK, FOUND CORROSION ON FRAME CLIP AT FRAME 85 BETWEEN STR 27R AND 28R. MAINTENANCE R & R OUT OF LIMITS CLIP, PN 170-66065-001 AT FRAME 85 BETWEEN STR 27R AND 28R IAW SRM 51-41-02. PROJECT NR 639RW-628 ITEM 3581 FOR WORK PERFORMED. ACFT REMAINS FOR COMPLETION.