What was found
WHILE AC WAS IN FOR HEAVY CHECK FOUND CENTER SHEAR PANEL AT FR 87 HAS CORROSION. MX REMOVED AND REPLACED CENTER SHEAR PANEL AT FR 87 PN 170-65928-001 IAW SRM 53-23-10, 51-42-01. AC REMAINS IN RME FOR COMPLETION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE AC WAS IN FOR HEAVY CHECK FOUND CENTER SHEAR PANEL AT FR 87 HAS CORROSION. MX REMOVED AND REPLACED CENTER SHEAR PANEL AT FR 87 PN 170-65928-001 IAW SRM 53-23-10, 51-42-01. AC REMAINS IN RME FOR COMPLETION.