What was found
CORRODED FLOOR SUPPORT BETWEEN FRAMES.87 AND 88. REMOVED THE DAMAGE. FOUND TO BE OUT OF LIMITS IAW SRM 53-23-10. REMOVED AND REPLACED THE FLOOR SUPPORT SRM 51-42-02, AND 51-42-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.