What was found
DURING A CHECK, FOUND THE AFT WET AREA CENTER SHEAR PANEL CORRODED, FRAMES 87 - 88. MX REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-10-03, 53-23-10, 51-42-01, AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A CHECK, FOUND THE AFT WET AREA CENTER SHEAR PANEL CORRODED, FRAMES 87 - 88. MX REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-10-03, 53-23-10, 51-42-01, AND 51-40-02.