What was found
CORROSION AS MARKED, RT FLOORBEAM FR 86-87 REMOVED AND INSTALLED NEW RT FLOORBEAM REF SRM 51-41-01, 51-42-01, 51-43-03. ACFT REMAINS IN HEAVY CHECK BNA
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AS MARKED, RT FLOORBEAM FR 86-87 REMOVED AND INSTALLED NEW RT FLOORBEAM REF SRM 51-41-01, 51-42-01, 51-43-03. ACFT REMAINS IN HEAVY CHECK BNA