What was found
WHILE IN HVY MX CHECK - CORROSION BELOW FLOORS REAR CARGO COMPARTMENT FR74 AND STRINGERS 29R-28R. REMOVED CORRODED SHEAR CLIP ON FRAME 74 AND STRINGERS 29R-28R. INSTALLED NEW SHEAR CLIP. REF EMB SRM 51-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HVY MX CHECK - CORROSION BELOW FLOORS REAR CARGO COMPARTMENT FR74 AND STRINGERS 29R-28R. REMOVED CORRODED SHEAR CLIP ON FRAME 74 AND STRINGERS 29R-28R. INSTALLED NEW SHEAR CLIP. REF EMB SRM 51-41-02.