What was found
AFT WET AREA BETWEEN FRAMES 87 AND 88, LBL 10 TO RBL 10 CENTER SHEAR PANEL IS CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-42-01, SRM 51-23-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA BETWEEN FRAMES 87 AND 88, LBL 10 TO RBL 10 CENTER SHEAR PANEL IS CORRODED. REMOVED AND REPLACED THE SHEAR PANEL IAW SRM 51-42-01, SRM 51-23-04.