What was found
MAINTENANCE FOUND THE FLOOR SUPPORT BETWEEN FRAMES 85 - 86 CORRODED. FOUND TO BE OUT OF LIMITS AND WAS REPLACED IAW SRM 51-41-01, 51-43-03, AND 51-40-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAINTENANCE FOUND THE FLOOR SUPPORT BETWEEN FRAMES 85 - 86 CORRODED. FOUND TO BE OUT OF LIMITS AND WAS REPLACED IAW SRM 51-41-01, 51-43-03, AND 51-40-03.