What was found
MX FOUND AFT WET AREA, GUSSET PLARE CORRODED.MATERIAL LOSS IS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED GUSSET IAW E175 SRM 51-41-01. PSE EFFECTIVE 53-23-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MX FOUND AFT WET AREA, GUSSET PLARE CORRODED.MATERIAL LOSS IS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED GUSSET IAW E175 SRM 51-41-01. PSE EFFECTIVE 53-23-005.